Menu

Precision Fluid Control Components · R&D / Manufacturing / OEM Support

Medical and consumables microfluidic chip coating: thermal grease case study

2025.10.07

Background

An equipment integrator / manufacturer in Medical and consumables needed to coating on a microfluidic chip using thermal grease.

Process challenge

Bead width and height must stay stable with no edge creep.

Solution

We recommended Screw Valve + Sensor, with tuning rotor/stator fit and flow path geometry to the filler particle size.

Result

  • Volume drift held within ±3% over an 8-hour run.
  • Shot volume 0.05 mL with deviation within ±2%.
  • Cycle time 1.0 s per dot with no stringing or dripping during continuous running.

Project facts

  • Industry: Medical and consumables
  • Workpiece: microfluidic chip
  • Fluid: thermal grease
  • Process: coating
  • Recommended lines: Screw Valve, Sensor
Enquiry Call us
189 2849 2979
WeChat Scan to add our WeChat Scan to add our WeChat
Email
amt@aimte.cn
Back to top